Latest Products http://www.rsenterprisesindia.co.in Latest Products Mon, 13 Jul 2020 08:44:15 +0530 en-us http://www.rsenterprisesindia.co.in Biofeedback Machine http://www.rsenterprisesindia.co.in/biofeedback-machine.htm http://www.rsenterprisesindia.co.in/biofeedback-machine.htm Thu, 14 Sep 2017 00:00:00 +0530 What is biofeedback Biofeedback is a technique in which people are trained to improve their health by learning to control certain internal bodily processes that normally occur involuntarily, such as heart rate, blood pressure, muscle tension and skin temperature. These activities can be measured with electrodes and displayed on a monitor that both the participant and his or her practitioner can see. The monitor provides feedback to the participant about the internal working of his or her body. This person can then be taught to use information to gain control over these "involuntary" activities. How does Ofeed back work Scientists are not able to explain exactly how or why biofeedback works, there does seem to be at least one common thread : most benefit form biofeedback have conditions that are brought on or made worse by stress for this reason, many scientist believe that relaxation is key to successful biofeedback therapy. What happens din a No feedback se Mon? In a normal biofeedback session, electrodes are attached to the skin. These electrodes then feed information to a small monitoring box that translates the physiologic response into a tone that lines moving in pitch, a visual meter that varies in brightness, or a computer screen that mental exercises. Through tries and error, people can learn to identify and control the mental activity that will bring about the desired physical changes. How many sessions wM 11 need Each session generally lasts less than one hour. The number of session required depends on the condition being treated. Many people being to see results within 8 to 10 sessions. Treatment of headache, incontinence, and Raynaud's disease (A condition that causes diminished blood flow to the fingers, toes, nose, or ears) requires at least 10 weekly sessions and then less frequent sessions as health improve. Conditions like high blood pressure, however, usually requires 20 weekly biofeedback sessions, you will also be taught mental before exercises and relaxation techniques that can be done at home and must be practices at least 5 to 10 minutes every day.Different Types of biofeedback : The six commonly used forms of biofeedback therapy are: Neuro feed back or electroencephalography (EEG), which measures brain wave activity Electromyography (EMG), which measures muscle tension Thermal biofeedback, which measures skin temperatures Pulse Rate GSR Biofeedback Respiration rate Biofeedback, which measures Respiration Rate Are there any ricks assnrim. pri with hindi primark Biofeedback is considered a safe procedure. No negative side effects have been report edow can I find a qualified pr Specialists who provide biofeedback training range from psychiatrist and psychologists to nurses, dentist, and physicians. Riof PP hark 6,1 Pc Select a game out of number of games provided. Playing our games you learn the skills of relaxation TMT Machine http://www.rsenterprisesindia.co.in/tmt-machine.htm http://www.rsenterprisesindia.co.in/tmt-machine.htm Thu, 14 Sep 2017 00:00:00 +0530 Features : Optica treadmill belt. lly isolated amplifier. State-of-the-art Windows based Stress Test Software. Digital filter for noise and distortion free recording. Crystal clear wave forms with steady base line ensured by innovative baseline correction algorithm. Wide range of comprehensive reports. Standard letter (8.5" x 11") or A4 papers withlwithout grid printing. Online/Offline printing. Post-test review and edit facility. Medicaid's in-house fabricated medical grade tread mill driven by 2.5 HP Japanese motor with apprehensive safety features. Easy availability of service and spares. Graphical representation of ST-HR trends. Performs both resting 12 lead ECGs and stress tests on one system. Axis and interval measurements (Resting ECG). Antistatic Modes Configuration Mode Hospital name, Doct0r's name, Designation, TM speed at exercise stop, Advance stage, Screen display leads, Stage report protocol, HR & ST alarm limits, Standard summary options, TM slope, User dehned TM protocols, Printout protocols. Acquisition Mode Patient details : Filter select, Multiple screen formats, Leads oft indication, Peak exercise median rn recovery stage. Review Mode To select patient from list and reprocess, to change HR & BP at any stage. Facility to On/Offgrid, view rhythm strip, edit and print summary report. Software : Test Protocols Pre-programmed protocols including Bruce, modified Bruce, Ellestad, Naughton and useredltable protocols. Storage Facility to store Medians every 8 secs, along with HR, BP and Fiducial points, l2 lead unaveraged ECG, l0secs. Rhythm strips for 12 leads. Printouts Automatic/Manual Online printing with Grid On/Oftfacility, print selected reports in queue. Minimum Computer Hardware Requirements ; Pentium—iii, 128 Nib Raivi, 1.44 Mb Fdd, 20 Gb Hdd, Cd-rom, Keyboard, Mouse, Usb Port, Serial Pon, Colour Monitor I5",   Operating System : Window 98/me/2000/xp. Printer Any Laser/inkjet Colour Printer Supporting windows, Medicaid also Manufacturers : Digital & analog Eeg, Video Eeg, Emg/ncv/ep, Pc Based Spirometer, Biofeedback "Bio-tra|ners" Eng Machine, and Bedside Ecg Monitor, Pc Based Ecg and "Card|ofax" Ecg Machines, Pulse oximeter ,Ectmachines, Polygraph, Studentphy s|ographetc. Repetitive Transcranial Magnetic Stimulator http://www.rsenterprisesindia.co.in/repetitive-transcranial-magnetic-stimulator.htm http://www.rsenterprisesindia.co.in/repetitive-transcranial-magnetic-stimulator.htm Tue, 19 Sep 2017 00:00:00 +0530 Owing to our well-maintained and organized inventory system, we deliver the same in the committed time. We are working in close coordination with the management and team members; they follow strict warehousing norms. We are able to keep the whole batch away from diverse damaging factors including sunlight, dust, moisture and rain.Advantages Medstim TMS : Highly effective (based on result of clinical research, TMS surpasses the Success rates of Pharmacotherapy intervention and ECT) Few or no side effects (most severe side effect is a mild headache) Quick onset of therapeutic effect (typically within 1 week) Painless procedure, Non—invasive, No anesthesia required Outpatient therapy Excellent ability to target specific neuron areas Effectiveness requires 2 to 3 week treatment AbiIity to provide therapeutic benefit for treatment—resistant individuals. Patients do not have to stop taking medication in order to receive TMS Equivalent effectiveness in treating both patients with Major Depressive Disorder and those sufferinq from Bipolar Disorder.   Application : Psychiatry : rTMS is very useful tool in treating Psychiatric disorders:- Bipolar disorder, Depression, Anxiety, OCD, Schizophrenia, ADHD and behavior disorders. Neurology : rTMS is also useful in the treatment of some neurological disorders:- Parkinson's disease, writer's cramp, stroke, neuropathic pain, migraine and tinnitus. Physiotherapy : Medstim is useful in rehabilitation and management of chronic pain. Pulse Oximeter http://www.rsenterprisesindia.co.in/pulse-oximeter.htm http://www.rsenterprisesindia.co.in/pulse-oximeter.htm Thu, 14 Sep 2017 00:00:00 +0530 We have a well-maintained and spacious storage space and thus, we are flexible enough of meeting the urgent needs. Furthermore, we by no means go out of stock and thus we maintain year round accessibility of all the products. Owing to our well-maintained and organized inventory system, we deliver the same in the committed time.Advantages : Mains cum battery powered. Programmable alarms for high-low pulse rate and SpO2 within set limits with adjustable volume. a Ideally suitable for Operation Theatres, ICU, NICU, OPD, Emergency Rooms or during emergency transport. Computer interface through specially designed software for complete disclosure analysis and printing. Audible pitch change in beep with change in percentage of SpO2. Back-lit LCD display for signal strength, bar graph and messages. OXY-EXCEL provides SpO2 and pulse rate measurement with bright LED display. 3 24 hours trend memory with 1 minute resolution for heart rate and SpO2 reading.   Optional Accessories PC software for online and offline review and printing Paediatric probe Portable Spirometer http://www.rsenterprisesindia.co.in/portable-spirometer.htm http://www.rsenterprisesindia.co.in/portable-spirometer.htm Thu, 14 Sep 2017 00:00:00 +0530 As we ensure complete safety of the products at our end, we follow stringent and organized warehousing system in our state-of-the-art warehouse. Moreover, the system is supervised by experts. We keep in consideration that the inputs (raw material) used are of incredible quality and meet the set industrial norms. Thus, the final products are as per the globally accepted quality standards.   Features : High Resolution colour TFT Screen Built in thermal array Printer Digital Turbine flow meter with high accuracy FVC, SVC and MVV test Storage for 200 patient data Mains & Battery operations Facility to transfer data to pc through USB   Technical Specification Power Supply – Rechargeable battery & Mains power Temperature – 0-50oC Flow measurement – Bi-directional digital turbine Volume measurement – Flow integration Flow Range – 0.03-20 I/S Volume range – 0-2 liters (BTPS) Flow accuracy - ï½± 2 % Volume Accuracy - ï½± 2 % interface – USB Display – 140x80mm Printer/Paper – thermal, 112 mm width Dimensions – 165x150x40mm Weight – 750gms   Standard accessories Digital Turbine – 01 USB cable - 01 Adult mouthpieces - 10 Adapter for pediatric mouthpieces - 01 Pediatric mouthpiece - 10 Nose Clips - 02 Operating manual - 01 Carrying Case - 01 PC ECG Machine http://www.rsenterprisesindia.co.in/pc-ecg-machine.htm http://www.rsenterprisesindia.co.in/pc-ecg-machine.htm Thu, 14 Sep 2017 00:00:00 +0530 Both of our online and offline payment processing methods are secure for transaction offering you a reliable assistance. We thus accept all kinds of cash payments as well as bank transfers. As a trusted name, we always make sure that our products are properly packed and remain free from damage during transit. For this, we have hired an adroit team of experts having immense experience in packaging. Features : Simultaneous acquisition of I2 leads. Automatic or manual measurements. Adjustable gain, sweep speed and filters. Select able lead colours on screen and on print outs, Storage on hard disk, floppies and CD-ROM. (Optional) Storage of different visits or multiple ECG pages in the same file for easy retrieval, record keeping and comparison. Easy connectivity with Laptop & Desktop PC. I Economical Print outs on a standard A4 size paper with & without grid. Automatic measurement of Amplitude of all I2 leads, AXIS (R QRS and T). Various intervals / duration, PR, RR, QRS, QT & QTc. Facility to print name of a disease and its impression on each page of the ECG data. Split Screen facility Comprehensive reports can be printed for all display types of Review and Analysis. Print card output in various formats. I Operating Systems Window - 95/98/ME. Transfer of ECG data via E-mail. Optional data storage in PDF format. Advanced patient data management. No hardware installations internal to the PC. EEG Machine http://www.rsenterprisesindia.co.in/eeg-machine.htm http://www.rsenterprisesindia.co.in/eeg-machine.htm Thu, 14 Sep 2017 00:00:00 +0530 Striving hard to provide the best in class range, we are a Siliguri(India) based company. We are backed with highly experience packaging experts and team members; they ensure that the packaging is done with utmost proficiency and keeping in mind the globally accepted norms.Features : Easy laptop connectivity. Ideally suitable in |CU’s. In—bui|t word processor for reporting. Brain Mapping. Optically Isolated. Auto Spike Detection. Operating system Windows XP. Comparison oftrlree montages simultaneously. Complete EEG transfer on CD & playback without additional software. Upgradable to Video EEG.   Technical Specification Max. no. of Display Channels NC - 2400 - 24 Channels NC - 3200 - 32 Channels A/D Conversion : 16 bit met Sampling Rate : 1024 Hz Sensitivity : 1 to 1000µv Low Pass Filter : 0.1,0.3, 1 &5Hz High Pass Filter : 15, 35,70, 100 Hz Notch Filter : 50/60 Hz on/off Sweep Speed : 7.5,15,30 & 60 mm /sec Input Impedance : >10 Mohm CMRR : >100db Noise Level : Less than 1uv Flash Rate 1 to 30 Hz Software Controlled Dimension : 195 x 165 x 50 mm Weight : 650 gms. (without laptop)   Standard Accessories Disc Electrodes - 50 nos. EEG Paste - 2 Jars. Ground Wire - 1 No. Interface Cable - 1 No. Photic Flash - 1 No. Installation CD - 1 No. Carry Bag - 1 No. ECT Machine http://www.rsenterprisesindia.co.in/ect-machine.htm http://www.rsenterprisesindia.co.in/ect-machine.htm Thu, 14 Sep 2017 00:00:00 +0530 We have a dedicated quality control department to ensure the products provided to you are as per international quality management systems. We are associated with a team of quality analysts who hold years of experience in this domain and conduct strict quality checks for ensure high quality of raw material as well as finished products.Features : Parameter display on LCD . Auto Stimulus Voltage Auto Impedance Check Output display in joules as well as in millicoulombs Truly Portable. ECG Machine http://www.rsenterprisesindia.co.in/ecg-machine.htm http://www.rsenterprisesindia.co.in/ecg-machine.htm Thu, 14 Sep 2017 00:00:00 +0530 Owing to our excellent in-house amenities in Siliguri(India), we deliver huge assortment of products to the customers. The packaging commences under the strict supervision of experts and other team members; they ensure that the products are packed sternly to circumvent loss during transit. EMG Machine http://www.rsenterprisesindia.co.in/emg-machine.htm http://www.rsenterprisesindia.co.in/emg-machine.htm Thu, 14 Sep 2017 00:00:00 +0530 To protect our products from being damaged during transit/ handling, we use industrial grade packaging materials. Furthermore, we ensure the packs are appealing for marketing purposes. In order to keep up the high-standards, we ensure from the very beginning that the raw materials used are as per the international standards. By this, we are capable of delivering the finest array of products.Introduction : Neurostim developed & design by highly qualified technocrats having rich experience of 30 years in Biomedical Instruments provides reliability & quality service to the Neurophysiological community. Neurostim is a complete system having facility to perform muscle EMG, complete nerve conduction studies Et Evoke potential. Neurostim is useful in the field of Neurology, Psychiatry, Physiology & Physiotherapy etc. After Sales back up : All equipments from Medicaid systems comes to you after thorough checking, testing & series of critical tests performed by the experienced & dedicated dealing hands to ensure better quality i.e. at par with world famous equipments and keep them functional hassle free. With the rapid change in technology the Medicaid's team of R&;;D engineers keep itself abreast with the latest technology for upgradation of the systems in order to compete world market. Medicaid's team consisting of expert dealing staffis always available for customer's services nation wide. By choosing Medicaid you always stay ahead of others. Clinical Electromyography (EMG) : Needle & surface EMG, Turn] Amplitude Analysis SDOUIEHEOUS, ll'l'[€f`fEl'El"IC€ PBTEEFTI O,—Motor Unit Potential Analysis {O.-IVI UAP) Trigger EMG, litter EMG Upto 13 minutes storage facility of complete EMG Data Cascade or full screen EMG Single / Dual] Four channel simultaneous acquisition   Highlights : Directly connect to USB port, no external power supply required Simultaneous acquiring and display of EMG from different group of muscles. Upto 13 minutes of continueous EMG wave form can be stored and replay with Audio. Simultaneous display of live and averages waveforms Auto marking of amplitude and latency More than one nerve can be listed on a single screen Comprehensive auto report generation with all test values in tabular form Report Printing in MS Word format In-built picture guide for muscle/nerves PSG Machine http://www.rsenterprisesindia.co.in/psg-machine.htm http://www.rsenterprisesindia.co.in/psg-machine.htm Thu, 14 Sep 2017 00:00:00 +0530 We own a substantial storage space that is well-structured and maintained by the professionals. The final packaging and storing of the products is done after complete serialization to avoid last minute hassle. Advanced shipping services, well-planned and organized facilities; we are flexible in presenting the product range with utmost safety.   Along with Video monitoring having following features :- Complete Patient data along with Video can be stored on CD, which can be viewed on any other comput On live audio recording. Facility to smooth scrolling of EEG data with Patient movements at same speed as in acquisition. Complete patient questionnaire before and after sleep study . In built word processor for Patient reporting . On line display of heart rate, RDI and sleep stages. On line printing of complete analysis of user selectable time. On line split screen to view data at different sweep speed. Automatic restart of test even on complete shut down.   Automatic Marking Provision :- Apneas & Hypopneas : (obstructive central or mixed apneas) Arousals, Destruction, Pulse Rate Spike detection sleep stages scoring Sleep spindles –K- Comlexes-Arousale-REM.   Following Reports Are Printed After The Test Is Completed sleep stages : S1,S2,S3,S4, REM, Wake time. Oxygen Destruction, HR Variation, Body Position. Limb movement, snoring, summary report   The System Comprises - Body Position Transducer - 01 No. SPO2 Probe - 01 No. Limb Movement Sensor - 01 No. Snoring Senor - 01 No. Mike for Room Audio Recording - 01 No. Respiration Belt Thoracic - 01 No. Respiration Belt Abdomen - 01 No. Nasal Flow Probe - 01 No. EMG Surface Electrodes - 10 Nos. EKG Limb Electrodes - 04 Nos. EOG Surface Electrodes - 06 Nos. EEG Disc Electrodes - 25 Nos. 10-20 Conductive Paste - 02 Nos. Earthing wire - 01 No. USB Cable - 01 No.   Details : EEG - 21 Channels. EOG - .02 Channels. EMG - 02 Channel. EKG - .01 Channel. PLM - 01 Channel Abdominal Effort - 01 Channel SPO2 - 01 Channel. Pulse - .01 Channel. Chest Respiration - 01 Channel. Air Flow - 01 Channel. Snoring - 01 Channel. Body Position - 01 Channel